Evaluasi Kapasitas Elemen Balok Dan Kolom Gedung Beton Bertulang Eksisting Akibat Perubahan Fungsi Ruang Berdasarkan Perubahan Beban Hidup Menggunakan Sap2000

Maulana, Hafidz (2026) Evaluasi Kapasitas Elemen Balok Dan Kolom Gedung Beton Bertulang Eksisting Akibat Perubahan Fungsi Ruang Berdasarkan Perubahan Beban Hidup Menggunakan Sap2000. Tugas_Akhir thesis, Universitas Kadiri.

[img] Text
01.Cover.pdf

Download (281kB)
[img] Text
02.abstrak.pdf

Download (293kB)
[img] Text
03.bab 1.pdf
Restricted to Repository staff only

Download (410kB)
[img] Text
04.daftar pustaka.pdf

Download (274kB)

Abstract

Changes in the function of spaces in existing reinforced concrete buildings require structural evaluation because changes in activities can affect the live loads acting on structural elements. This condition applies to the Preventive Healthcare Service Building of Bhayangkara Hospital, Kediri, where a patient room is planned to be converted into a gym. This study aims to analyze changes in structural response, evaluate beam and column capacities, and explain the mechanisms of changes in structural behavior due to changes in live loads. The study employed a quantitative evaluative approach using SAP2000 structural modeling by comparing two conditions: the patient room and the gym. Live load determination was based on SNI 1727:2020, while structural capacity evaluation referred to SNI 2847:2019. The analyzed response parameters included axial force (Pu), shear force (Vu), and bending moment (Mu) in beams B1–B3 and columns K1–K2. Element capacity was evaluated using the Demand–Capacity Ratio (DCR). The results showed that the live load increased from 1.92 kN/m² to 4.79 kN/m², representing an increase of 2.87 kN/m² or 149.48%. This change affected Pu, Vu, and Mu, although the direction of change varied among structural elements. The evaluation showed that all DCR values for the assessed parameters were below 1.00, with the highest flexural DCR of 0.536 occurring in beam B1. For the columns, the P–M interaction DCR values were 0.353 for K1 and 0.338 for K2, while the shear DCR values were 0.156 and 0.162, respectively. These results indicate that the demands on the beams and columns remain below their design capacities for the parameters evaluated. Changes in structural behavior occur through changes in live loads, which affect internal forces, structural demand, utilization levels, and the capacity evaluation of structural elements. Keywords: change in room function, live load, structural response, element capacity, DCR, SAP2000.

Item Type: Thesis (Tugas_Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Teknik > Prodi Teknik Sipil S1